High-Quality Piezoelectric Property, Offer One-Step Service!
Piezoelectric ceramic can be used in the beauty industry and medical surgery.
Cause piezo material is a high-quality asymmetry that leads to the conversion of electric signals into physical deformation and conversely physical deformation into an electric signal. It covers the piezoelectric properties of materials found inside the human body including blood vessels, skin, and bones as well as how the piezoelectricity innate in those materials aids in disease treatment. It also covers piezoelectric materials and their use in medical implants by explaining how piezoelectric materials can be used as sensors and can emulate natural materials. Finally, the possibility of using piezoelectric materials to design medical equipment and how current models can be improved by further research is explored. This review is intended to provide a greater understanding of how important piezoelectricity is to the medical industry by describing the challenges and opportunities regarding its future development.
Piezoelectric Ceramic for the Beauty industry application:
Ultrasonic beauty relieving tool
Piezoelectric disc Ceramic (PZT) for Ultrasonic Beauty Vibrator
Model | Dimension (mm) | Thickness Frequency Fr(MHz) | Capacitance C(pf) | Impedance Zt(Ω) | Electromechanical coupling coefficient Kt (%) | Electrodes arrangement |
---|---|---|---|---|---|---|
HS-P416004 | Ø16×0.4 | 5.0±5% | 5400±15% | ≤5 | ≥45 | electrodes on the same side |
HS-P416021 | Ø16×2.1 | 1.0±5% | 1000±15% | ≤4 | ≥45 | electrodes on the same side |
HS-P420020 | Ø20×2.0 | 1.0±5% | 1650±15% | ≤4 | ≥45 | electrodes on each side |
HS-P425004 | Ø25×0.4 | 5.0±5% | 12800±15% | ≤4 | ≥45 | electrodes on the same side |
HS-P425010 | Ø25×1.0 | 2.0±5% | 5800±15% | ≤4 | ≥45 | electrodes on the same side |
HS-P425020 | Ø25×2.0 | 1.0±5% | 2700±15% | ≤4 | ≥45 | electrodes on each side |
HS-P428010 | Ø28×1.0 | 2.0±5% | 6940±15% | ≤4 | ≥45 | electrodes on the same side |
HS-P428017 | Ø28×1.7 | 1.2±5% | 3880±15% | ≤3 | ≥45 | electrodes on the same side |
HS-P428020 | Ø28×2.0 | 1.0±5% | 3300±15% | ≤3 | ≥45 | electrodes on the same side |
HS-P450020 | Ø50×2.0 | 1.0±5% | 10000±15% | ≤3 | ≥45 | electrodes on the same side |
HS-P460020 | Ø60×2.0 | 1.0±5% | 14500±15% | ≤3 | ≥45 | electrodes on the same side |
Piezoelectric Ceramic for medical applications:
- HIFU Transducer
- Ulthera
- Ultrasonic Slimming
Features:
- High intensity focused Ultrasound piezo
- High frequency: 1MHz~8MHz
- Focus Length: 10mm~100mm
- Strong Electrode: Ag by CO-FIRED
- Long lifetime: High Power pulse>15,000 Hours
HIFU Piezo ceramic dimension Model & Specifications
Model | OD (diameter mm) | Bending (mm) | Frequency (KHz) |
---|---|---|---|
HS-940R55-250 | 94 | 55 | 250±10KHz |
HS-750R405-250 | 75 | 40.5 | 250±10KHz |
HS-140R160-7.0 | 14 | 16 | 7.0Mhz±3% |
HS-140R160-4.0 | 14 | 16 | 4.0Mhz±3% |
HS-170R190-4.0 | 17 | 19 | 4.0Mhz±3% |
HS-198R170-4.0 | 19.8 | 17 | 4.0Mhz±3% |
HS-198R190-4.0 | 19.8 | 19 | 4.0Mhz±3% |
HS-195R190-4.0 | 19.5 | 19 | 4.0Mhz±3% |
HS-189R190-4.0 | 18.9 | 19 | 4.0Mhz±3% |
HS-195R190-3.0 | 19.5 | 19 | 3.0Mhz±3% |
HS-195R285-4.0 | 19.5 | 28.5 | 3.0Mhz±3% |
HS-198R280-4.0 | 19.8 | 28 | 4.0Mhz±3% |
HS-195R250-4.0 | 19.5 | 25 | 4.0Mhz±3% |
HS-380R380-2.0 | 38 | 38 | 2.0Mhz±3% |
HS-250R330-2.0 | 25 | 33 | 2.0Mhz±3% |
HS-300R350-2.0 | 30 | 35 | 2.0Mhz±3% |
HS-198R280-2.0 | 19.8 | 28 | 2.0Mhz±3% |